Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Experimental Hematology ; (6): 904-910, 2019.
Article in Chinese | WPRIM | ID: wpr-771864

ABSTRACT

OBJECTIVE@#To investigate the gene mutations types and the clinical characteristics in 3 patients with hereditary coagulation factor Ⅶ deficiency.@*METHODS@#The phenotype diagnosis was validated by detecting the coagulation parameters including prothrombin time (PT),activated partial thromboplastin time (APTT), fibrinogen (FIB), FⅦ activity (FⅦ: C) and specific antigens (FⅦ: Ag) of proband and its family members. All exons, exon-intron boundaries, 5' untranslated regions and 3' untranslated regions of F7 gene were amplified with PCR. Potential mutations were detected by direct sequencing of purified PCR products. Suspected mutations were confirmed by sequencing of the opposite strand.@*RESULTS@#A total of 5 different mutations were identified in 3 patients with hereditary coagulation factor Ⅶ deficiency and family members, including 4 misssense mutations and 1 splice site mutation. Out of 3 cases of hereditary coagulation factor Ⅶ deficiency 2 had double heterozygous mutation, I had homozygous mutations. Patient 1 had p.His408Gln with p.Arg413Gln double heterozygous mutations, her sister had p.His408Gln with p.Arg413Gln double heterozygous mutations, another one had p.His408Gln mono-heterozygous mutation, their correspo FⅦ: C were 5%, 3%, 75%. Patient 2 had p.Arg364Gln with p.His408Gln double heterozygous mutations, her brother had p.Arg364Gln with IVS6-1G>A double heterozygous mutations, their corresponding FⅦ: C were 2.0%, 2.0%. Patient 3 had p.Arg337Cys homozygous mutation, FⅦ: C was 3.0%.@*CONCLUSION@#A total of 5 different mutations were identified in 3 patients with hereditary coagulation factor Ⅶ deficiency, the p.His408Gln is a common mutation, the FⅦ: C and FⅦ: Ag have no correlation with clinical phenotypes.


Subject(s)
Female , Humans , Male , Factor VII , Factor VII Deficiency , Heterozygote , Homozygote , Mutation , Pedigree , Phenotype
2.
Journal of Zhejiang University. Medical sciences ; (6): 160-163, 2014.
Article in Chinese | WPRIM | ID: wpr-336725

ABSTRACT

<p><b>OBJECTIVE</b>To determine the enantiomeric impurity contents of domestic timolol maleate in bulk drugs and eye drops.</p><p><b>METHODS</b>Enantiomer impurity of timolol was assayed by chiral high performance liquid chromatography. The chromatographic conditions were as follows:chiralcel OD chiral column (4.6 mm ×150 mm, 5μm), detection wavelength:297 nm, mobile phase:hexane-isopropanol-diethylamine (480:20:1), column temperature:25 ℃, flow rate:1.0 ml/min, sample injection volume:5 μl.</p><p><b>RESULTS</b>The resolution between R- and S-timolol was more than 4. The enantiomeric impurity contents were less than 0.67% on average in two batches of timolol maleate bulk drugs, and 0.31% on average in three batches of timolol maleate eye drops.</p><p><b>CONCLUSION</b>Enantiomeric impurity contents in each batch of products all meet European Pharmacopoeia criteria, which can be used as references in Chinese Pharmacopoeia criteria.</p>


Subject(s)
Chromatography, High Pressure Liquid , Methods , Drug Contamination , Ophthalmic Solutions , Reference Standards , Stereoisomerism , Timolol , Reference Standards
3.
Journal of Zhejiang University. Medical sciences ; (6): 164-167, 2014.
Article in Chinese | WPRIM | ID: wpr-336724

ABSTRACT

<p><b>OBJECTIVE</b>To determine the contents of L-enantiomer impurity in valaciclovir hydrochloride.</p><p><b>METHODS</b>Valaciclovir enantiomers were separated and determined by using chiral high performance liquid chromatography. Chromatographic conditions were as follows:CROWNPAK(®) CR(+) chiral column (4 mm×150 mm, 5 μm), detection wavelength:254 nm, mobile phase:water-methanol-perchloric acid (19:1:0.1), flow rate:0.75 ml/min, sample injection volume:10 μl.</p><p><b>RESULTS</b>D-valaciclovir was completely separated from L-enantiomer impurity. The contents of L-enantiomer impurity were 0.65%-2.62% on average in 8 batches of valaciclovir hydrochloride.</p><p><b>CONCLUSION</b>Enantiomeric impurity contents in each batch of products were all meet criteria of United States Pharmacopeia, which can be used in criteria of Chinese Pharmacopeia as references.</p>


Subject(s)
Acyclovir , Chromatography, High Pressure Liquid , Methods , Stereoisomerism , Valine
SELECTION OF CITATIONS
SEARCH DETAIL